CPU 013

013-CCF0R00 - CPUs | CPUs STEP7 programmable, C class

Order no.

013-CCF0R00

Type CPU 013C
Module ID -

General information

Note -
Features Powered by SPEED7
Work memory [KB]: 64...128
Onboard 16x DI / 12x DO / 2x AI [voltage 0...10 V] ] / 4x Counter / 2x [PWM/Pulse Train]
Interface [2x RJ45]: active Ethernet PG/OP communication with DHCP support, switch, ModbusTCP master/slave, openCommunication, I-Device, PROFINET IO controller (8 devices)
Interface [RS485]: MPI, PtP: ASCII, STX/ETX, 3964 (R), USS master, Modbus master/slave
Optional: PROFIBUS master/slave
Web server
SD card slot with locking, up to 64 expansion modules, configurable with SPEED7 Studio, SIMATIC Manager and TIA Portal

Technical data power supply

Power supply (rated value) DC 24 V
Power supply (permitted range) DC 20.4...28.8 V
Reverse polarity protection
Current consumption (no-load operation) 120 mA
Current consumption (rated value) 360 mA
Inrush current 3 A
I²t 0.1 A²s
Max. current drain at backplane bus 1 A
Max. current drain load supply 6 A
Power loss 7 W

Technical data digital inputs

Number of inputs 16
Cable length, shielded 1000 m
Cable length, unshielded 600 m
Rated load voltage DC 24 V
Reverse polarity protection of rated load voltage
Current consumption from load voltage L+ (without load) 25 mA
Rated value DC 24 V
Input voltage for signal "0" DC 0...5 V
Input voltage for signal "1" DC 15...28.8 V
Input voltage hysteresis -
Signal logic input Sinking input
Frequency range -
Input resistance -
Input current for signal "1" 3 mA
Connection of Two-Wire-BEROs possible
Max. permissible BERO quiescent current 0.5 mA
Input delay of "0" to "1" 3 µs – 15 ms / 0.5 ms – 15 ms
Input delay of "1" to "0" 3 µs – 15 ms / 0.5 ms – 15 ms
Number of simultaneously utilizable inputs horizontal configuration 16
Number of simultaneously utilizable inputs vertical configuration 16
Input characteristic curve IEC 61131-2, type 1
Initial data size 16 Bit

Technical data digital outputs

Number of outputs 12
Cable length, shielded 1000 m
Cable length, unshielded 600 m
Rated load voltage DC 24 V
Reverse polarity protection of rated load voltage
Current consumption from load voltage L+ (without load) 20 mA
Total current per group, horizontal configuration, 40°C 6 A
Total current per group, horizontal configuration, 60°C 6 A
Total current per group, vertical configuration 6 A
Output voltage signal "1" at min. current L+ (-0.8 V)
Output voltage signal "1" at max. current L+ (-0.8 V)
Output current at signal "1", rated value 0.5 A
Signal logic output Sourcing output
Output current, permitted range to 40°C 5 mA to 0.6 A
Output current, permitted range to 60°C 5 mA to 0.6 A
Output current at signal "0" max. (residual current) 0.5 mA
Output delay of "0" to "1" 2 µs / 30 µs
Output delay of "1" to "0" 3 µs / 175 µs
Minimum load current -
Lamp load 10 W
Parallel switching of outputs for redundant control of a load not possible
Parallel switching of outputs for increased power not possible
Actuation of digital input
Switching frequency with resistive load max. 1000 Hz
Switching frequency with inductive load max. 0.5 Hz
Switching frequency on lamp load max. 10 Hz
Internal limitation of inductive shut-off voltage L+ (-45 V)
Short-circuit protection of output yes, electronic
Trigger level 1 A
Number of operating cycle of relay outputs -
Switching capacity of contacts -
Output data size 12 Bit

Technical data analog inputs

Number of inputs 2
Cable length, shielded 200 m
Rated load voltage -
Reverse polarity protection of rated load voltage -
Current consumption from load voltage L+ (without load) -
Voltage inputs
Min. input resistance (voltage range) 100 kΩ
Input voltage ranges 0 V ... +10 V
Operational limit of voltage ranges +/-3.5%
Operational limit of voltage ranges with SFU -
Basic error limit voltage ranges +/-3.0%
Basic error limit voltage ranges with SFU -
Destruction limit voltage max. 30V
Current inputs -
Max. input resistance (current range) -
Input current ranges -
Operational limit of current ranges -
Operational limit of current ranges with SFU -
Basic error limit current ranges -
Radical error limit current ranges with SFU -
Destruction limit current inputs (electrical current) -
Destruction limit current inputs (voltage) -
Resistance inputs -
Resistance ranges -
Operational limit of resistor ranges -
Operational limit of resistor ranges with SFU -
Basic error limit -
Basic error limit with SFU -
Destruction limit resistance inputs -
Resistance thermometer inputs -
Resistance thermometer ranges -
Operational limit of resistance thermometer ranges -
Operational limit of resistance thermometer ranges with SFU -
Basic error limit thermoresistor ranges -
Basic error limit thermoresistor ranges with SFU -
Destruction limit resistance thermometer inputs -
Thermocouple inputs -
Thermocouple ranges -
Operational limit of thermocouple ranges -
Operational limit of thermocouple ranges with SFU -
Basic error limit thermoelement ranges -
Basic error limit thermoelement ranges with SFU -
Destruction limit thermocouple inputs -
Programmable temperature compensation -
External temperature compensation -
Internal temperature compensation -
Technical unit of temperature measurement -
Resolution in bit 12
Measurement principle successive approximation
Basic conversion time 0.5 ms
Noise suppression for frequency 40 dB
Initial data size 4 Byte

Technical data analog outputs

Number of outputs -
Cable length, shielded -
Rated load voltage -
Reverse polarity protection of rated load voltage -
Current consumption from load voltage L+ (without load) -
Voltage output short-circuit protection -
Voltage outputs -
Min. load resistance (voltage range) -
Max. capacitive load (current range) -
Max. inductive load (current range) -
Output voltage ranges -
Operational limit of voltage ranges -
Basic error limit voltage ranges with SFU -
Destruction limit against external applied voltage -
Current outputs -
Max. in load resistance (current range) -
Max. inductive load (current range) -
Typ. open circuit voltage current output -
Output current ranges -
Operational limit of current ranges -
Radical error limit current ranges with SFU -
Destruction limit against external applied voltage -
Settling time for ohmic load -
Settling time for capacitive load -
Settling time for inductive load -
Resolution in bit -
Conversion time -
Substitute value can be applied -
Output data size -

Technical data counters

Number of counters 4
Counter width 32 Bit
Maximum input frequency 100 kHz
Maximum count frequency 400 kHz
Mode incremental encoder
Mode pulse / direction
Mode pulse
Mode frequency counter
Mode period measurement
Gate input available
Latch input available
Reset input available -
Counter output available

Load and working memory

Load memory, integrated 128 KB
Load memory, maximum 128 KB
Work memory, integrated 64 KB
Work memory, maximal 128 KB
Memory divided in 50% program / 50% data
Memory card slot SD/MMC-Card with max. 2 GB

Hardware configuration

Racks, max. 5
Modules per rack, max. total max. 64 minus number line extensions
Number of integrated DP master -
Number of DP master via CP -
Operable function modules 64
Operable communication modules PtP 64
Operable communication modules LAN -

Status information, alarms, diagnostics

Status display yes
Interrupts yes
Process alarm yes
Diagnostic interrupt yes
Diagnostic functions yes, parameterizable
Diagnostics information read-out possible
Supply voltage display green LED
Group error display red SF LED
Channel error display red LED per group

Isolation

Between channels
Between channels of groups to 16
Between channels and backplane bus
Between channels and power supply -
Max. potential difference between circuits DC 75 V/ AC 50 V
Max. potential difference between inputs (Ucm) -
Max. potential difference between Mana and Mintern (Uiso) -
Max. potential difference between inputs and Mana (Ucm) -
Max. potential difference between inputs and Mintern (Uiso) -
Max. potential difference between Mintern and outputs -
Insulation tested with DC 500 V

Command processing times

Bit instructions, min. 0.02 µs
Word instruction, min. 0.02 µs
Double integer arithmetic, min. 0.02 µs
Floating-point arithmetic, min. 0.12 µs

Timers/Counters and their retentive characteristics

Number of S7 counters 512
S7 counter remanence adjustable 0 up to 256
S7 counter remanence adjustable C0 .. C7
Number of S7 times 512
S7 times remanence adjustable 0 up to 256
S7 times remanence adjustable not retentive

Data range and retentive characteristic

Number of flags 8192 Byte
Bit memories retentive characteristic adjustable adjustable 0 up to 256
Bit memories retentive characteristic preset MB0 .. MB15
Number of data blocks 1024
Max. data blocks size 64 KB
Max. local data size per execution level 4096 Byte

Blocks

Number of OBs 22
Number of FBs 1024
Number of FCs 1024
Maximum nesting depth per priority class 16
Maximum nesting depth additional within an error OB 4

Time

Real-time clock buffered
Clock buffered period (min.) 30 d
Accuracy (max. deviation per day) 10 s
Number of operating hours counter 8
Clock synchronization
Synchronization via MPI Master/Slave
Synchronization via Ethernet (NTP) no

Address areas (I/O)

Input I/O address area 2048 Byte
Output I/O address area 2048 Byte
Input process image maximal 2048 Byte
Output process image maximal 2048 Byte
Digital inputs 16224
Digital outputs 16256
Digital inputs central 528
Digital outputs central 524
Integrated digital inputs 16
Integrated digital outputs 12
Analog inputs 1015
Analog outputs 1015
Analog inputs, central 514
Analog outputs, central 256
Integrated analog inputs 2
Integrated analog outputs -

Technical data encoder supply

Number of outputs 1
Output voltage (typ) L+ (-1.5 V)
Output voltage (rated value) 300 mA
Short-circuit protection yes, electronic
Binding of potential Power supply of PLC

Communication functions

PG/OP channel
Global data communication
Number of GD circuits, max. 8
Size of GD packets, max. 54 Byte
S7 basic communication
S7 basic communication, user data per job 76 Byte
S7 communication
S7 communication as server
S7 communication as client -
S7 communication, user data per job 160 Byte
Number of connections, max. 32

PWM data

PWM channels 2
PWM time basis 1 µs / 0.1 ms / 1 ms
Period length 50µs...65.535ms / 0.1...87ms / 1...87ms
Minimum pulse width 0...0.5 * Period duration
Type of output Highside

Functionality Sub-D interfaces

Type X3
Type of interface RS485
Connector Sub-D, 9-pin, female
Electrically isolated
MPI
MP²I (MPI/RS232) -
DP master optional
DP slave optional
Point-to-point interface
5V DC Power supply max. 90mA, isolated
24V DC Power supply max. 100mA, non-isolated
 
Type -
Type of interface -
Connector -
Electrically isolated -
MPI -
MP²I (MPI/RS232) -
DP master -
DP slave -
Point-to-point interface -
5V DC Power supply -
24V DC Power supply -

Functionality MPI

Number of connections, max. 32
PG/OP channel
Routing
Global data communication
S7 basic communication
S7 communication
S7 communication as server
S7 communication as client -
Transmission speed, min. 19.2 kbit/s
Transmission speed, max. 12 Mbit/s

Functionality PROFIBUS master

Number of connections, max. 32
PG/OP channel
Routing
S7 basic communication
S7 communication
S7 communication as server
S7 communication as client -
Activation/deactivation of DP slaves
Direct data exchange (slave-to-slave communication) -
DPV1
Transmission speed, min. 9.6 kbit/s
Transmission speed, max. 12 Mbit/s
Number of DP slaves, max. 32
Address range inputs, max. 2 KB
Address range outputs, max. 2 KB
User data inputs per slave, max. 244 Byte
User data outputs per slave, max. 244 Byte

Functionality PROFIBUS slave

Number of connections, max. 32
PG/OP channel
Routing
S7 communication
S7 communication as server
S7 communication as client -
Direct data exchange (slave-to-slave communication) -
DPV1
Transmission speed, min. 9.6 kbit/s
Transmission speed, max. 12 Mbit/s
Automatic detection of transmission speed
Transfer memory inputs, max. 244 Byte
Transfer memory outputs, max. 244 Byte
Address areas, max. 32
User data per address area, max. 32 Byte

Functionality RJ45 interfaces

Type X1/X2
Type of interface Ethernet 10/100 MBit Switch
Connector 2 x RJ45
Electrically isolated
PG/OP channel
Number of connections, max. 4
Productive connections
Fieldbus -
 
Type -
Type of interface -
Connector -
Electrically isolated -
PG/OP channel -
Number of connections, max. -
Productive connections -
Fieldbus -

Point-to-point communication

PtP communication
Interface isolated
RS232 interface -
RS422 interface -
RS485 interface
Connector Sub-D, 9-pin, female
Transmission speed, min. 1200 bit/s
Transmission speed, max. 115.5 kbit/s
Cable length, max. 500 m

Point-to-point protocol

ASCII protocol
STX/ETX protocol
3964(R) protocol
RK512 protocol -
USS master protocol
Modbus master protocol
Modbus slave protocol
Special protocols -

Properties PROFINET I/O-Controller via PG/OP

Realtime Class -
Conformance Class PROFINET IO
Number of  PN IO devices 8
IRT support -
Shared Device supported
MRP Client supported
Prioritized start-up -
Number of PN IO lines 1
Address range inputs, max. 2 KB
Address range outputs, max. 2 KB
Transmiting clock 1 ms
Update time 1 ms .. 512 ms
Isochronous mode -
Parallel operation as controller and I-Device

Properties PROFINET I-Device via PG/OP

I/O Data range, max. 768 Byte
Update time 1 ms .. 512 ms
Mode as Shared I-Device -

Management & diagnosis via PG/OP

Protocols ICMP
DCP
LLDP / SNMP
NTP
Web based diagnosis
NCM diagnosis -

Ethernet communication via PG/OP

Number of productive connections via PG/OP, max. 2
Number of productive connections by Siemens NetPro, max. 2
S7 connections BSEND, BRCV, GET, PUT, Connection of active and passive data handling
User data per S7 connection, max. 64 KB
TCP-connections FETCH PASSIV, WRITE PASSIV, Connection of passive data handling
User data per TCP connection, max. 8 KB
ISO on TCP connections (RFC 1006) FETCH PASSIV, WRITE PASSIV, Connection of passive data handling
User data per ISO connection, max. 8 KB

Ethernet open communication via PG/OP

Number of configurable connections, max. 2
ISO on TCP connections (RFC 1006) TSEND, TRCV, TCON, TDISCON
User data per ISO on TCP connection, max. 32 KB
TCP-Connections native TSEND, TRCV, TCON, TDISCON
User data per native TCP connection, max. 32 KB
User data per ad hoc TCP connection, max. 1460 Byte
UDP-connections TUSEND, TURCV
User data per UDP connection, max. 1472 Byte

WebVisu via PG/OP

WebVisu is supported
Max. number of connections WebVisu 4
WebVisu supports HTTP
WebVisu supports HTTPS

Housing

Material PPE / PPE GF10
Mounting Profile rail 35 mm

Mechanical data

Dimensions (WxHxD) 147 mm x 100 mm x 83 mm
Net weight 320 g
Weight including accessories 320 g
Gross weight 355 g

Environmental conditions

Operating temperature 0 °C to 60 °C
Storage temperature -25 °C to 70 °C

Certifications

UL certification yes
KC certification yes